Allen & Heath DR66 Architect's Specification The unit shall be a digital mix processor with 6 analogue inputs and 6 analogue outputs. The unit shall have a full crosspoint matrix, comprising 36 points, allowing any input, or combination of inputs, to be routed to any output or combination of outputs. All crosspoints shall have a variable level. The 2 mic/line inputs and 6 line level outputs shall be on balanced XLRs with level trims. The 4 stereo line inputs shall sum to mono and be on RCA phono connectors with level trims. Comprehensive ducking capability shall be provided. The mic/line inputs shall have internal jumpers for pad and phantom power selection. The mic/line gain range shall be 6dB to 55dB with input impedance of 2k ohms (no pad) or 10kohms (pad). The phono input gain sensitivity shall be internally link-adjustable from -10dBv to +4dBu with an impedance of 10k ohms. The inputs shall be converted using a 20 bit analogue-to-digital converter. The XLR outputs shall have a link-selectable sensitivity from -10dBV to +4dBu with an output impedance of 50 ohms. The conversion shall be by a 20 bit digital-to-analogue converter. The unit shall be configured over a standard RS232 port using a proprietary 32-bit Windows(tm) based software application with a Graphical User Interface. Configurations shall be editable both on and off-line. The configuration shall determine the allocation of internal signal processing resources to input and output channels, as well as routing, passwords, levels and channel names. After configuration, the unit shall run standalone, without an external computer. Signal processing resources available shall include compressors, gates, limiters, graphic equalisers, parametric equalisers and crossovers. An optional expander card shall provide the facility for additional signal processing resources or supplementary delay resources. The unit shall use Flash memory to permit firmware upgrades via the RS232 port. An internal real-time clock shall allow scheduling of timed events. The unit shall be compatible with BS5839 installation requirements. The hybrid switched/linear power supply shall allow emergency operation with a single 24V external battery and the unit shall interface with alarm systems. The total power consumption shall be no more than 20VA and the permissible incoming mains voltage range shall be configurable to 100, 120, 220 or 230 VAC. The front panel shall feature 8 installer-definable function keys for user control of volume levels and patches. There shall also be a backlit LCD for indication of setup menus, peak conditions, patch status and channel levels. Important system parameters, such as Patch Naming, Channel Naming, Limiter control, Ducking control, Phase reversal, Routing assignments, Date/Time, LCD contrast and Soft Key definitions shall be password-protected from user adjustment. Facilities for remote control of unit parameters shall be provided. The unit shall weigh no more than 7kg in a 1U rack-mount chassis. The chassis shall be constructed from zintec steel and feature a removable top for configuration of internal jumpers and presets. The unit shall be the Allen & Heath DR66 digital mix processor.